Connected oil condensing boiler

Connected oil condensing boiler

OptiCondens

Connected oil condensing boiler
Very High Energy Performance
Bio-fuel F30 compatible
Power 24 and 32 kW
Heating only or Heating and hot water production integrated
Flue gas connection by suction cup
Ideal for underfloor heating or underfloor heating and radiators


Connected condensing oil boilers, bio-fuel compatible 10, 24 kW or 32 kW, ErP 2018 certified.

  • Etas > 91 %

Contents

Class 7 control (RC7)
Bio-fuel compatible F30
Optimal energy for better comfort
Perge: Oil condensing boiler technology
Models and accessories

 

Class 7 control (RC7)


RC7 is a class VII control system, which acts simultaneously on the temperature of the heating circuit:
- by modulating it according to the external climatic conditions;
- by adapting and correcting it according to the room requirements.

The temperature sensors are easy to install and transmit information either by wire or by radio. The device is controlled by your smartphone using the MyPerge application, available on Google Play (Android) or Apple Store (iOS). The connection is made locally via Bluetooth or internet or remotely via internet. Data exchanges are encrypted for greater security. You can control up to 3 heating circuits or 2 heating circuits + 1 domestic hot water circuit.

You have 4 operating modes:

- Winter (heating + DHW)
- Summer (DHW only)
- Absence (heating only at a programmed frost-free temperature)
- Standby (no heating or DHW)

 

Bio-fuel F30 compatible

PERGE has always invested in innovative technologies, particularly in clean combustion techniques.

This pragmatic approach is based on a process of permanent progress, even if it is minor, to improve the daily life of all. This is why PERGE OptiCondens oil condensing boilers are compatible with Bio-fuel F30.

 

Optimal energy for greater comfort


Very high energy performance
PERGE OptiCondens condensing boilers are very high energy performance boilers and easily meet the requirements of the European Eco-design Directive both in terms of efficiency and low pollutant emissions:
- Etas efficiency higher than 91% ;
- NOx emissions below 120 mg/Nm3.

The efficiency of PERGE OptiCondens condensing boilers is up to 104.6%.

Economical and easy to install

DuothermPERGE OptiCondens oil-fired boilers can easily supply two heating circuits with different temperatures (e.g. underfloor heating + radiator circuit) directly from the boiler and without additional hydraulic accessories.
This simplifies the hydraulic installation and reduces installation times

More comfort

The PERGE RC7 room temperature control is integrated as standard in the OptiCondens Connect+ models, for more comfort at lower cost. This means that the OptiCondens Connect+ boiler operates at the exact temperature you need.

The hot water models are equipped with a stainless steel tank with priority heating of the upper part. This means that the water is quickly available at the point of use, even if a lot of water is drawn off: 200 litres of hot water at 40° in 10 minutes with the 90-litre tank, 270 litres of hot water at 40° in 10 minutes with the 150-litre tank (cold water at 10°, domestic hot water storage at 65°).

 

 

Perge: Oil condensing boiler technology

Robust and simple

Stotherm

Thanks to the Stoptherm device, the dew point is avoided without the installation of a mixing valve. The optional RTE3 outdoor temperature control for OptiCondens oil condensing boilers guarantees automatic operation at a temperature adjusted to your needs.

The 904L stainless steel tube bundle condenser is made of high quality material and provides top performance.

The models with DHW production are equipped with a 90 or 150 litre 316L stainless steel anti-legionella tank.

 

 


Garantie 10 ansExchanger body warranty: 10 years. The guarantee on the exchanger body is extended from 3 to 10 years if an annual maintenance contract is signed with a professional, from the time the boiler is commissioned and without interruption for 10 years.

 

 

 

Models and accessories


Equipment present on all models:

- Heating body allowing, without mixing valve, an operation without limitation of return temperature, without risk of dew point inside the heating body.
- Oil burner with flue gas recirculation for improved combustion hygiene.
- 904L stainless steel tube bundle condenser
- Circulator circuit n°1
- Control panel
- Reinforced insulation jacket

V: Airtight fireplace for connection to a chimney or to a horizontal, vertical or separate flue.
D: Duotherm device for direct supply of 2 heating circuits at different temperatures.
F: Fuel oil
F30 : Bio-fuel F30

 

Bio-fuel F30 : 

Designation kW DHW RC7 Etas
OptiCondens 24 C-F30VDR Connect 24 / 91,0
OptiCondens 32 C-F30VDR Connect 32 / 93,2
OptiCondens 24 B90-F30VDR Connect 24 90 litres stainless steel 91,0
OptiCondens 24 B150-F30VDR Connect 24 150 litres stainless steel 91,0
OptiCondens 32 B150-F30VDR Connect 32 150 litres stainless steel 93,2

 

Standard oil fuel : 

 

Designation kW DHW RC7 Etas
OptiCondens 24 C-FVDR Connect 24 / 91,0
OptiCondens 32 C-FVDR Connect 32 / 93,2
OptiCondens 24 B90-FVDR Connect 24 90 litres stainless steel 91,0
OptiCondens 24 B150-FVDR Connect 24 150 litres stainless steel 91,0
OptiCondens 32 B150-FVDR Connect 32  150 litres stainless steel 93,2

 

 

o : optional equipment 

 

 

 

Price examples

OptiCondens Connect 32 B150 C-F30VDR

OptiCondens Connect 32 B150 C-F30VDR

32 kW connected biofuel condensing boiler with 150 litre stainless steel tank
Boiler with 2 heating circuits at different temperatures (underfloor heating + radiators)
Factory fitted equipment: heating body, 904L stainless steel condenser, burner, circuit n°1 heating pump, control panel, reinforced insulation jacket.
Price excluding tax

7.803,00 € HT
OptiCondens Connect 24 C-F30VDR

OptiCondens Connect 24 C-F30VDR

Connected biofuel condensing boiler with a power of 24 kW
Boiler with 2 heating circuits at different temperatures (underfloor heating + radiators)
Factory fitted equipment: heating body, 904L stainless steel condenser, burner, circuit n°1 heating pump, control panel, reinforced insulation jacket.
Price excluding tax

6.188,00 € HT

Why choose oil ?

Oil is easy to store and available everywhere. Moreover, it is a very powerful fuel (10 kWh per liter)

Oil has greatly changed in order to reduce its environmental impact. The oil condensing boiler technology allows to reduce energy consumption significantly (Up to 30% compared to a traditional boiler). Its level of sulphur has been divided by 6 in the last 40 years.

Oil boilers may be twinned with renewable fuels such as biomass or solar powered system.

Manufacturer requirements

  • Chimney installations and Ventilation should conform to requirements of the Building Regulations and any approved local laws and all subsequent standards referred to.

Do you need more information ?